Alarm display
CM
.
Indication
An nCBsy under the peripheral module (PM) subsystem header indicates a
minor alarm that involves an remote maintenance module (RMM). This
header appears at the maintenance (MTC) level of the MAP display.
Meaning
The n indicates the number of RMMs in the central-side (C-side) busy (CBsy)
state.
Impact
Subscriber service is not affected. Local RMM backup is not available when
the unit fails.
Common procedures
There are no common procedures.
Action
This procedure contains a summary flowchart and a list of steps. Use the
flowchart to review the procedure. Use the steps to perform the procedure.