Nortel DMS-100 Series Maintenance Manual page 520

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-180 OPM card replacement procedures
NT6X60
in an OPM HIE
19
20
21
297-8361-550 Standard 04.01 September 2000
(continued)
where
lcm_unit
is the LCM unit (0 or 1)
Note: Repeat this step until both units of the LCM are aligned to the new
RG.
If SWRG command
passed
failed
Test the new RG by typing
>TST UNIT lcm_unit_no
and pressing the Enter key.
where
lcm_unit_no
is the number of the LCM unit posted in step 4
Example of a MAP response:
LCM REM1 14 1 Unit 0 InSvce Tests Initiated LCM REM1 14 1 Unit 0 Tst
Passed
If TST
passed
failed
If required align RG activity to the preferred RG by typing
>SWRG UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the LCM unit (0 or 1)
Note: Repeat this step until both units of the LCM are aligned to the
preferred RG.
If the SWRG command
passed
failed
Send any faulty cards for repair according to local procedure.
Do
step 19
step 23
Do
step20
step 23
Do
step 21
step 23

Advertisement