Nortel DMS-100 Series Maintenance Manual page 407

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

17
Determine the type of device on which the PM load files are located.
If load files are located on
tape
IOC disk
SLM disk
18
Locate the tape that contains the PM load files.
At the IOE frame
19
Mount the tape on a magnetic tape drive.
At the MAP display
20
Download the tape by typing
>MOUNT tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
21
List the contents of the tape in your user directory by typing
>LIST T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files.
22
Release the tape drive from your user directory by typing
>DEMOUNT T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive mounted in step 20.
23
Go to step 34.
24
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
25
Access the disk utility level of the MAP by typing
>DSKUT
and pressing the Enter key.
OPM card replacement procedures
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM HIE
Do
step 18
step 24
step 29
8-67
NT2X70
(continued)

Advertisement

Table of Contents
loading

Table of Contents