RMM contains its own processor, which performs scanning of the service
circuits and digit collection during ESA.
The RMM C-side interface uses a pair of DS30A links, one to each LCC in the
HIE shelf. The DS30A links ensure the RMM is operable, regardless of which
LCC is active. The LCC passes maintenance requests from the host to the
RMM and provides a link between the RMM and line circuits in the LCA. At
the host office, PRLCM maintenance is directed to the RMM using the MAP
terminal. The following figure shows how the RMM communicates with both
the host and the LCA through the LCC.
Figure 3-4 RMM connection with host and LCA through LCC
Host

Frame supervisory panel

The FSP occupies shelf position 60 of the RLCC cabinet. The FSP provides
talk jacks, fuse alarm features, and power control for the RLCM. The FSP
contains 48-V distribution breakers to the four cards that control the alarm
facilities and power converters in the RLCC cabinet. These cards and their
functions are as follows:
NT6X36AA Alarm card
This card is used to monitor the power converters in the RLCC cabinet, and
generate an alarm when an undervoltage condition occurs in any of the
power converters.
NT6X36AC Fan Alarm card
This card is used to monitor the power in the RLCC cabinet related to the
fan cooling units located below shelf 05 which provides cooling for the
RLCM-EDC cabinet, and generates an alarm when an undervoltage or fan
failure condition occurs in the cabinet.
NT0X91AA Alarm and Converter Drive
RMM
DS30A
link pair
PCM30
Link
links
control
cards
DMS-100 Family OPM Maintenance Manual XPM14 and up
PRLCM overview 3-9
LCA-0
DS30A links
LCA-1