23
Access the disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
24
List all disk volumes to user directory by typing
>LV CM
and pressing the enter key.
25
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 22.
26
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
27
Reload the RMM by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
28
Return the RMM unit to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
29
Go to the TTP level of the MAP and post the RMM by typing
>TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
OPM card replacement procedures
in an OPM RMM
DMS-100 Family OPM Maintenance Manual XPM14 and up
Do
step 33
step 28
Do
step 29
step 33
8-195
NT6X74
(continued)

Advertisement