Nortel DMS-100 Series Maintenance Manual page 504

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-164 OPM card replacement procedures
NT6X53
in an OPM
(end)
32
33
34
35
36
37
38
297-8361-550 Standard 04.01 September 2000
lcm_unit
is the LCM unit (0 or 1)to be loaded
If
load failed
load passed
Use the following information to determine the next step in this procedure.
If you entered this procedure
an alarm clearing procedure
other
Return the LCM unit to service by typing
>RTS UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the LCM (0 or 1) busied in step 4
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card.
Go to step 38.
Return to the Alarm Clearing Procedure that directed you to this procedure.
If necessary, go to the point where the faulty card list was produced, identify
the next faulty card on the list, and go to the appropriate card replacement
procedure for that card in this manual.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have successfully completed this procedure.
Do
step 37
step 32
Do
step 36
step 33
Do
step 34
step 37

Advertisement

Table of Contents
loading