Nortel DMS-100 Series Maintenance Manual page 102

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

2-26 Functional overview
control the alarm facilities and power converters in the OPM cabinet. These
circuit packs and associated functions follow:
This circuit pack controls the alarms and power for the following:
The FSP also contains additional circuit breakers (CB) for distribution of
-48-V power to the different shelves in the OPM cabinet. Refer to the table
FSP circuit breaker assignments for the following information:
Table 9 FSP circuit breaker assignments
CB
Shelf type
CB1
HIE
CB2
HIE
CB3
HIE
CB4
HIE
CB5
RMM
297-8361-550 Standard 04.02 December 2004
NT6X36AA Alarm card
This card monitors the power converters in the OPM cabinet. This card
generates an alarm when an undervoltage condition occurs in any of the
power converters.
NT0X91AA Alarm and Converter Drive
This circuit pack controls the alarms and power for the NT6X53AA power
converter for unit 1 of the LCM and the NT2X70AA. The NT2X70AA is
in slot position 22 of the HIE.
NT0X91AE Converter Drive and Protection Circuit
the NT6X53AA power converter for unit 0 of the LCM
the NT2X70AA in slot position 25 of the HIE
the NT2X09AA/NT2X06BA, in the correct slot positions of 17 and 20 of
the RMM
CB power distribution
assignments
shelf type
slot position
product engineering code (PEC) code
equipment supported
Shelf pos.
38
38
38
38
56
Slot pos.
PEC code
25
NT2X70
01
NT6X60
05
NT6X60
22
NT2X70
17
NT2X09/NT2X06
Equipment
LCA 0
RG 0
RG 1
LCA 1
RMM