Nortel DMS-100 Series Maintenance Manual page 316

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-96 OPM alarm clearing procedures
RMM
minor
(continued)
5
6
7
8
297-8361-550 Standard 04.01 September 2000
To identify the OPM with links that are busied by the system (SysB), type:
>TRNSL C
and press the Enter key.
Example of a MAP response
LINK
0:
LCM OPM 00 0
LINK
1:
LCM OPM 00 0
To post the OPM identified in step 5, type:
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the OPM (alphanumeric)
frame
is the frame number of the OPM (0-511)
lcm
is the number of the LCM
WARNING
If you do not allow the time required for the system to clear the
alarm, a false alarm indication occurs.
Allow 3 to 5 min for the system to clear the alarm then
proceed to the next step.
To identify the peripheral-side (P-side) links that have defects, type:
>TRNSL P
and press the Enter key.
Example of a MAP response:
LINK 0: RMM 0 0;CAP MS;STATUS:SysB,;MSGCOND: CLS
LINK 1: RMM 0 1;CAP MS;STATUS:
LINK 2: ESA 0 0;CAP
LINK 4: ESA 0 1;CAP
To busy the link that has defects, type:
>BSY LINK
link_no
and press the Enter key.
where
0;CAP MS;STATUS:SysB,;MSGCOND:CLS
1;CAP MS;STATUS:
OK,;MSGCOND: OPN
S;STATUS:
OK,;MSGCOND: OPN
S;STATUS:
OK,;MSGCOND: OPN
OK,;MSGCOND:OPN