8-176 OPM card replacement procedures
NT6X60
in an OPM HIE
Replacing an NT6X60 card in an HIE
At your Current Location
1
2
3
At the MAP
4
297-8361-550 Standard 04.01 September 2000
(continued)
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or were directed to this procedure by your maintenance
support group.
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC) including suffix, as the card that is to be
removed.
If you were directed to this procedure from the Alarm Clearing Procedures ,
go to step 9. Otherwise, continue with step 4.
Access the PM level and post the LCM by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the name of the site at which the LCM is located
frame
is the number of the frame (0 to 511)
lcm
is the number of the LCM (0 to 199)
Example of a MAP display:
CAUTION
Loss of service
This procedure includes directions to manually busy one or
more peripheral module (PM) units. Since manually busying
a PM unit can cause service degradation, perform this
procedure only if necessary to restore out-of-service
components. Otherwise, carry out this procedure during
periods of low traffic.