8-168 OPM card replacement procedures
NT6X54
in an OPM
(continued)
LCM
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
5
6
7
8
297-8361-550 Standard 04.01 September 2000
CM
MS
IOD
Net
.
.
.
.
SysB
0 Quit
PM
0
2 Post_
LCM
0
3
4 SwRg
LCM
5 Trnsl
Unit–0:
6 Tst
Unit–1:
7 Bsy
8 RTS
Drwr: 01 23 45 67 89 01 23 45 67 89
9 OffL
Note: ILDR drawers are identified in reverse video on the MAP display.
Determine whether or not you need to access the ILD level on the MAP
terminal.
If the card you are replacing is
NT6X54DA
NT6X54AA
Access the ILD level on the MAP terminal by typing
>ILD
and pressing the Enter key.
Post the ILDR drawer in which the card is being replaced by typing
>POST drawer_no
and pressing the Enter key.
where
drawer_no
is the ILD drawer number (0 through 19) in the LCM
Busy both line subgroups associated with the LCM drawer in which the card
is being replaced by typing
>BSY DRWR
and pressing the Enter key.
PM
CCS
LNS
1LCM
.
.
ManB
OffL
CBsy
1
0
1
0
Rem1
OO O ISTb
Links_OOS: CSide 0 PSide 0
InSv
Mtce
/RG:
InsV
Mtce
/RG:
11 11 11 11 11 RG:Pref:0 InSv
.. .. SS .. .. .. .. .. .. ..
Do
step 6
step 9
Trks
Ext
Appl
.
.
.
ISTb
InSv
0
0
130
0
0
0
0
0
Stby:1 InSv