Lcm Critical - Nortel DMS-100 Series Maintenance Manual

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-2 OPM alarm clearing procedures
LCM
critical
Alarm display
CM
.
Indication
Use this procedure to restore service in an outside plant module (OPM) when
both units of the line concentrating module (LCM) are out of service (OOS).
This condition always produces a central-side busy (CBsy) alarm.
The LCM alarm appears under the peripheral module (PM) header in the MAP
subsystem display. This alarm indicates an alarm condition in the OPM. The
n indicates the number of LCMs with alarms. The *C* that appears under the
alarm indicates a critical alarm.
Meaning
Both units of the LCM are CBsy.
Result
Call processing ceases with critical alarm indication.
Common procedures
There are no common procedures.
Action
The following flowchart provides a summary of the procedure. Use the
flowchart to review the step-action procedure. Follow the steps to perform the
procedure.
Note: The numbers represented in the flowchart do not coincide with the
step-action numbers. The numbers indicate movement within the flowchart.
297-8361-550 Standard 04.01 September 2000
MS
IOD
Net
.
.
.
PM
CCS
Lns
nLCM
.
.
*C*
Trks
Ext
Appl
.
.
.