Clearing an RMM minor alarm
At the MAP terminal
1
Enter this procedure from a step in the PM system level alarm clearing procedure. This
step identifies a PM alarm associated with an OPM fault.
To silence the alarm, type:
>MAPCI;MTC;PM;SIL
and press the Enter key.
2
To identify the RMM that has defects, type:
>DISP STATE ISTB
and press the Enter key.
Example of a MAP response
ISTb
RMM: 2
3
To post the ISTb RMM from step 2, type:
>POST RMM
and press the Enter key.
where
rmm_no
is the number of the RMM that has defects
4
To perform an in-service test on the RMM that has defects type:
>TST
and press the Enter key.
If test
passes
fails because of C-side links not
available
fails and the system produces a
card list
fails and the system does not
produce a card list
OPM alarm clearing procedures
ATTENTION
RMM
rmm_no
DMS-100 Family OPM Maintenance Manual XPM14 and up
minor
Do
step 17
step 5
step 14
step 16
7-95
RMM
(continued)