8-82 OPM card replacement procedures
NT2X90
in an OPM RMM
12
13
14
15
16
17
297-8361-550 Standard 04.01 September 2000
(end)
and pressing the Enter key.
If the RTS
passes
fails
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card.
Go to step 17.
Return to the Alarm Clearing Procedures that directed you to this card
replacement procedure. If necessary, go to the point where the faulty card list
was produced, identify the next faulty card on the list, and go to the
appropriate replacement procedure in this manual for that card.
Obtain further assistance in replacing this card by contacting personnel
responsible for higher level of support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.