Nortel DMS-100 Series Maintenance Manual page 332

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-112 OPM alarm clearing procedures
PM PES
critical, major, minor
Impact
A PES alarm does not affect subscriber service directly.
Common procedures
There are no common procedures.
Action
This procedure contains a summary flowchart and a list of steps. Use the
flowchart to review the procedure. Follow the steps to perform the procedure.
297-8361-550 Standard 04.01 September 2000
(continued)
AUDIT
state of the battery rotation and testing audit
.
audit enabled
DIS
audit disabled
WEEK
mode of battery rotation and testing audit
n
battery strings 1–4, audit enabled for normal
rotation and testing
.
audit enabled, ac or rectifier failure
P/S
post ac failure recovery mode (short outage)
P/E
post ac failure recovery mode (extended outage)

Advertisement

Table of Contents
loading

Table of Contents