and press the Enter key.
16
To RTS the PM, type:
>RTS PM
and press the Enter key.
If RTS
passed
failed
17
To identify the OPM that has faults and display the LCM by site, type:
>DISP STATE SYSB LCM
and press the Enter key.
If response
indicates no SysB LCMs
indicates SysB LCMs
18
To post the OPM with the alarm condition, type:
>POST LCM SYSB
and press the Enter key.
19
To determine if the OPM is equipped with emergency stand-alone (ESA),
type:
>QUERYPM
and press the Enter key.
Example of a MAP response:
CAUTION
If you do not allow the time required for the system to clear the
alarm, a false alarm indication occurs.
Allow 3 to 5 m for the system to clear the alarm before you
proceed to the next step.
DMS-100 Family OPM Maintenance Manual XPM14 and up
OPM alarm clearing procedures
critical
Do
step 40
step 33
Do
step 40
step 18
7-9