Nortel DMS-100 Series Maintenance Manual page 501

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Determine the correct FSP switch for the shelf in which the power converter
was replaced from the diagram below. The switches are numbered
corresponding to the shelf position.
Circuit breaker
CB6
CB7
CB6
CB6
CB7
CB7
3. Turn the circuit breaker on for the unit with the new power converter.
a. The converter fail LED will be extinguished.
b. The frame fail lamp on the FSP will be extinguished.
12
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 13.
At the MAP display
13
Load the LCM unit by typing
>LOADPM UNIT lcm_unit CC
and pressing the Enter key.
where
lcm_unit
is the LCM unit (0 or 1)to be loaded
If
message "loadfile not found in
directory" is received
load pases
OPM card replacement procedures
Unit FED
LCA 0
LCA 1
LCA 0
LCA 0
LCA 1
LCA 1
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM
Locations
Shelf 04 slot 01
(OPM)
Shelf 21 slot 01
(OPM)
Row A bay 0 slot 01
(OPM-640)
Row A bay 0 slot 01
(OPM-256)
Row A bay 0 slot 01
(OPM-640)
Row A bay 0 slot 23
(OPM-256)
Do
step 14
step 33
8-161
NT6X53
(continued)