8-64 OPM card replacement procedures
NT2X70
in an OPM HIE
5
6
297-8361-550 Standard 04.01 September 2000
(continued)
Busy unit 0 of the OPM by typing
>BSY UNIT 0
and pressing the Enter key.
Post the ESA processor identified in step 4 by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor associated with the faulty NT2X70
card.
Busy the ESA processor by typing
>BSY
and pressing the Enter key.
Example of a MAP response:
This action will take this PM out of service
Please confirm ("Yes" or "No")
Respond to the system prompt by typing
>YES
CAUTION
Loss of service
This procedure contains directions to busy one or more
peripheral modules (PM) in a frame. Since busying a PM
affects subscriber service, replace power converters only
during periods of low traffic.