If the system
does not generate a card list
9
Check the card list that appears at the MAP display.
Example of a MAP response:
SITE FLR RPOS BAY_ID
REM1 01
A00
REM1 01
A00
REM1 01
A00
REM1 01
A00
10
Determine if you replaced the NT6X60 card.
If you
replaced the NT6X60 card
did not replace the NT6X60 card step 17
11
To return the LCM unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the ManB LCM unit (0 or 1)
If RTS
passes
fails
12
To align RG activity to the new RG, type
>SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the new RG
OPM alarm clearing procedures
SHF DESCRIPTION SLOT EQPEC
OPE 00
05
LCM:14 1
OPE 00
19
LCM:14 1
OPE 00
05
LCM:14 1
OPE 00
33
LCM:14 1
DMS-100 Family OPM Maintenance Manual XPM14 and up
critical
Do
step 18
:01
6X60
:04
6X51
:05
6X60
:04
6X51
Do
step 18
Do
step 12
step 18
7-21
LCM (RG)
(continued)