32
To test the RMM, type:
>TST
and press the Enter key.
If test
passes
fails, and the system produces a
cardlist
fails, and the system does not
produce a cardlist
33
To return the ManB RMM to service, type:
>RTS
and press the Enter key.
If RTS
passes
fails
34
The card list identifies the cards with possible faults. Replace the cards one
at a time according to this procedure.
If you
replaced all the cards on the list
did not replace all the cards on
the list
35
Go to the card replacement procedure in the Card Replacement Procedures
for the next card on the card list. When you finish with the card replacement
procedures, go to step 7.
36
For additional help, contact the next level of maintenance.
37
The procedure is complete. If other alarms appear at the MAP display, refer
to the appropriate alarm clearing procedures.
OPM alarm clearing procedures
DMS-100 Family OPM Maintenance Manual XPM14 and up