8-58 OPM card replacement procedures
NT2X59
in an OPM RMM
7
297-8361-550 Standard 04.01 September 2000
(continued)
a
Locate the card to be removed on the appropriate shelf.
b
Open the locking levers on the card to be replaced and gently pull the
card towards you until it clears the shelf.
c
Ensure that the replacement card has the same PEC including suffix, as
the card you just removed.
Open the locking levers on the replacement card.
Align the card with the slots in the shelf and gently slide the card into the shelf.