18
To attempt to load the OPM unit, type
>LOADPM UNIT
and press the Enter key.
where
lcm_unit
is the LCM unit to be loaded (0 or 1)
If load
is successful
is not successful
19
To attempt to return the OPM unit to service, type
>RTS UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit to return to service (0 or 1)
If RTS
passes
fails
20
The card list identifies the cards with possible faults. Replace the cards one
at a time in the order listed:
If you
did not replace all the cards on
the list
replaced all the cards on the list step 21
21
For additional help to clear this fault, contact the next level of support.
22
To replace the first (or next) card on the card list go to the Card Replacement
Procedures . For an OPM, notify outside operating company personnel that
you are changing the card. Go to step 17 when you replace the card.
23
The procedure is complete. If additional alarms display, refer to the
appropriate how to clear an alarm procedure.
OPM alarm clearing procedures
lcm_unit CC
DMS-100 Family OPM Maintenance Manual XPM14 and up
major
Do
step 19
step 21
Do
step 23
step 21
Do
step 22
7-45
LCM
(end)