Rlcm Talk Battery Alarm Critical - Nortel DMS-100 Series Maintenance Manual

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Alarm display
CM
.
Indication
An nLCM indicates a critical alarm that involves an RLCM. This nLCM
appears under the PM subsystem header with a *C* under the nLCM at the
MTC level of the MAP display.
Meaning
One or both units of the RLCM does not have a talk battery.
Result
If this condition affects CB8, call processing ends without an alarm
indication If this condition affects circuit breaker CB9, call processing ends
and a critical alarm occurs.
Common procedures
There are no common procedures.
Action
This procedure contains a summary flowchart and a list of steps to clear an
alarm. A detailed step-action procedure follows the flowchart.
MS
IOD
Net
.
.
.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
7-27
RLCM alarm clearing procedures
RLCM talk battery alarm
PM
CCS
Lns
nLCM
.
.
*C*
critical
Trks
Ext
Appl
.
.
.
7-27
7-27

Advertisement

Table of Contents
loading

Table of Contents