Switching Over The Inverter Control (Command Data Set); Advanced Commissioning - Siemens SINAMICS G110M Operating Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

6.2.6

Switching over the inverter control (command data set)

In some applications, it must be possible to switch over the master control for operating the
inverter.
Example: The motor is to be operable either from a central control via the fieldbus or via the
local digital inputs of the inverter.
Command data set (CDS)
This means that you can set the inverter con-
trol in various ways and toggle between the
settings. For instance, as described above,
the inverter can either be operated via a
fieldbus or via its digital inputs.
The settings in the inverter, which are as-
signed to a specific master control, are termed
the command data set.
You select the command data set using parameter p0810. To do this, you must interconnect
parameter p0810 with a control command of your choice, e.g. a digital input.
Figure 6-14
As in the example above, you obtain the interconnection if you configured the interfaces of
the inverter with p0015 = 7 in the basic commissioning, also see section
commissioning (Page 101).
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG
Example for the various command data sets

Advanced commissioning

6.2 Inverter control
Basic
163

Advertisement

Table of Contents
loading

Table of Contents