An incorrect phase sequence (fan rotates the wrong way) may create a risk of the unit
overheating.
To test this, check whether, looking from above, the fan is rotating in a counterclockwise
direction (i.e. to the left).
Notice: Risk of injury due to rotating parts.
6.9.5

Open-loop and closed-loop control section

Table 6- 28
Terminal type, open-loop and closed-loop control section
X177:
Type
Connection capacity
Stripped length
X178, X179:
Type
Connection capacity
Stripped length
XR1, XS1, XT1:
Type
Connection capacity
Stripped length
Tightening torque
X126:
Type
X100, X101:
Type
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
WARNING
SPT 1.5 spring-loaded terminal
Rigid/flexible/conductor sizes (mm
Flexible with end sleeve without/with plastic sleeve:
0.25-1.5/0.25-0.75 mm
10 mm
FMC 1.5 plug-in terminal
Rigid/flexible/conductor sizes (mm
Flexible with end sleeve without/with plastic sleeve: 0.25-1.5/0.25-0.75 mm
10 mm
MSTB 2.5/CIF plug-in terminal
Rigid/flexible/conductor sizes (mm
Flexible with end sleeve without/with plastic sleeve: 0.25-2.5/0.25-2.5 mm
7 mm
0.5 - 0.6 Nm
Submin D, 9-pin
Modular jack 8/4 (RJ45)
6.9 Assignment of terminals and connectors
/mm
/AWG): 0.2-1.5/0.2-1.5/24-16
2
2
(stripped length 8 mm)
2
/mm
/AWG): 0.2-1.5/0.2-1.5/24-16
2
2
/mm
/AWG): 0.2-2.5/0.2-2.5/24-12
2
2
Connecting
2
2
157