Qos; Table 43: Acl Log Messages; Table 44: Cos Log Message; Table 45: Diffserv Log Messages - D-Link DWS-4000 Series Cli Command Reference

Hide thumbs Also See for DWS-4000 Series:
Table of Contents

Advertisement

D-Link Unified Switch CLI Command Reference
Component
Message
Protocol Based
pbVlanCnfgrInitPhase2Process: Unable to register
VLANs
pbVlan callback with vlans
Protocol Based
pbVlanCnfgrInitPhase2Process: Unable to register
VLANs
pbVlan callback with nvStore
Q
S
O
Component
Message
ACL
Total number of ACL rules (x) exceeds max (y) on
intf i.
ACL
ACL name , rule x : This rule is not being logged
ACL
aclLogTask: error logging ACL rule trap for
correlator number
IP ACL number : Forced truncation of one or more
ACL
rules during config migration
Component
Message
COS
cosCnfgrInitPhase3Process: Unable to apply
saved config -- using factory defaults
Component
Message
DiffServ
diffserv.c 165: diffServRestore Failed to reset
DiffServ. Recommend resetting device
DiffServ
Policy invalid for service intf: "policy name ,
intIfNum x , direction y
© 2009 D-Link Corporation. All Rights Reserved
532
Table 42: Protocol-based VLANs Log Messages

Table 43: ACL Log Messages

Table 44: CoS Log Message

Table 45: DiffServ Log Messages

Cause
Appears when vlanRegisterForChange fails to
register pbVlan for vlan changes.
Appears when nvStoreRegister fails to register
save and restore functions for configuration save.
Cause
The combination of all ACLs applied to an interface
has resulted in requiring more rules than the
platform supports.
The ACL configuration has resulted in a
requirement for more logging rules than the
platform supports. The specified rule is functioning
normally except for the logging action.
The system was unable to send an SNMP trap for
this ACL rule which contains a logging attribute.
While processing the saved configuration, the
system encountered an ACL with more rules than
is supported by the current version. This may
happen when code is updated to a version
supporting fewer rules per ACL than the previous
version.
Cause
The COS component was unable to apply the
saved configuration and has initialized to the
factory default settings.
Cause
While attempting to clear the running configuration
an error was encountered in removing the current
settings. This may lead to an inconsistent state in
the system and resetting is advised.
The DiffServ policy definition is not compatible with
the capabilities of the interface specified. Check
the platform release notes for information on
configuration limitations.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwl-8600ap

Table of Contents