D-Link DWS-4000 Series Cli Command Reference page 485

Hide thumbs Also See for DWS-4000 Series:
Table of Contents

Advertisement

no serial baudrate
This command sets the communication rate of the terminal interface.
Format
no serial baudrate
Mode
Line Config
serial timeout
This command specifies the maximum connect time (in minutes) without console activity. A value of 0 indicates that a
console can be connected indefinitely. The time range is 0 to 160.
Default
5
Format
serial timeout <0-160>
Mode
Line Config
no serial timeout
This command sets the maximum connect time (in minutes) without console activity.
Format
no serial timeout
Mode
Line Config
show serial
This command displays serial communication settings for the switch.
Format
show serial
Modes
• Privileged EXEC
• User EXEC
Term
Definition
Serial Port Login
The time, in minutes, of inactivity on a Serial port connection, after which the Switch will close the
Timeout (minutes)
connection. Any numeric value between 0 and 160 is allowed, the factory default is 5. A value of 0
disables the timeout.
Baud Rate (bps)
The default baud rate at which the serial port will try to connect. The available values are 1200, 2400,
4800, 9600, 19200, 38400,57600, and 115200 baud. The factory default is 9600 baud.
Character Size
The number of bits in a character. The number of bits is always 8.
(bits)
Flow Control
Whether Hardware Flow-Control is enabled or disabled. Hardware Flow Control is always disabled.
Stop Bits
The number of Stop bits per character. The number of Stop bits is always 1.
Parity Type
The Parity Method used on the Serial Port. The Parity Method is always None.
Console Port Access Commands
477

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwl-8600ap

Table of Contents