T-1 Alarm Programming; Enable/Disable (Carrier Loss Alarm) - Vodavi STARPLUS STSe Operation Manual

Starplus stse key systems
Hide thumbs Also See for STARPLUS STSe:
Table of Contents

Advertisement

T-1 Alarm Programming

T-1 Alarm Programming
Description
The T-1 Trunk card and the system software provide tools to help detect and isolate problems
which may occur with the T-1 circuit. There are six LEDs mounted on the outside edge of the
T-1 Trunk card which either light or flash to indicate a variety of conditions on the T-1 circuit.
The Central Office Maintenance Center can send a command to place the CSU into Line Loop
Back mode. If there is no CSU, the T-1 Trunk card responds to the Line Loop Back command.
The buttons on the digital telephone are defined as shown below when entering the T-1
Alarm programming area:
Programming Steps
If the system is in the programming mode, continue using the program codes. If starting to
program here, enter the programming mode.
1. Press FLASH and dial [47]. The following message displays:
2. Press a button (1-7) that represents the desired alarm setting.
These settings govern all T-1 Trunk cards installed in the system.
The LED lights steady when the button is pressed.
Once the desired alarm is selected, the following conditions can be programmed:
Button #12 = Clears the alarm
Button #13 = Minor threshold setting
Button #14 = Major threshold setting
Button #15 = Time period for Minor/Major alarms
Button #16 = Sends LCD message of Major alarms to first Attendant Station

Enable/Disable (Carrier Loss Alarm)

Description
A Receive Carrier Loss (RCL) condition is declared when no bits have been received by the T-1
Trunk card for 150ms. It causes an Out of Frame (OOF) condition, and 2.5 seconds later a RED
Carrier Failure Alarm (CFA) state. During the time the RCL and RED alarm are declared,
incoming and outgoing signal bits are frozen. Outgoing calls cannot be made.
Programming Steps
1. Press the CARRIER LOSS flexible button (FLASH 47, Button #1). Button #1 and Button
#11 LEDs are lit steady. The following message displays:
STARPLUS STSe - Programming & Operations Manual
T 1 A L A RM
E N T E R B U T TO N N U MBE R
C A RR I ER LOS S
E N AB LE D
Features and Operation
0-1
2-299
August 2005