Co Line Attributes; Initialize Co Line Attributes - Vodavi STARPLUS STSe Operation Manual

Starplus stse key systems
Hide thumbs Also See for STARPLUS STSe:
Table of Contents

Advertisement

2-68
Features and Operation

CO Line Attributes

Initialize CO Line Attributes

Description
CO Line parameters may be initialized to set all data fields to their original, default values. The
following data fields are returned to their default value upon initializing the CO Line
Attributes.
Program
Code
FLASH 40
PAGE A
FLASH 40
PAGE B
STARPLUS STSe - Programming & Operations Manual
Table 2-4: CO Line Attribute Defaults
Flexible
Button
1
DTMF/Dial Pulse Programming
2
CO/PBX Programming
3
Universal Night Answer (UNA)
4
DISA CO-to-CO (Per CO Line)
5
Privacy
6
Loop Supervision Programming
7
DISA Programming
8
CO Line Group Programming
9
Class of Service (COS) Programming
10
CO Line Ringing Assignments
11
CO Line Identification Display
12
CO Direction
13
Display Ring Assignments
14
DID/TIE Signal
15
911 Trunk
17
Tenant Group CO Line Programming
1
T-1 Signal Type
2
T-1Ringback
3
T-1 Dial Tone
4
Transmit Volume
5
Preset Call Forward Destination
6
Preset Forward Voice Mail ID
7
Universal Day Answer (UDA)
8
Music-On-Hold (per CO Line)
9
Ring Tone (per CO Line)
16
Preset Call Forward Night Destination
17
Preset Call Forward Special Destination
18
Fax Detect Enable/Disable
Features
CO Line Attributes
Default Value
(after initialization)
DTMF
CO
Enabled
Enabled
Enabled
4=400 ms
None
Group 01
COS 1
None
Line XXX
Incoming/Outgoing
100A
Wink
Disabled
All Lines Group 0
Loop
Enabled
Disabled
5=0 db
None
None
Disabled
Channel 1
Tone # 00
None
None
Disabled
August 2005

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents