2-82
Features and Operation

Release Timer

Description
The Release Timer option allows the user to adjust the release timer on a per CO Line basis.
The release timer is used on ground start type trunks.
This timer is a lead filter timer. The CO must remove ground from the tip lead for longer than
this timer in order for the system to recognize it.
Programming Steps
1. Press FLASH and dial [40]. The following message displays:
2. Enter a valid number for the range of lines being programmed. If only one line is being
programmed, enter that number twice (001 001).
3. Press Button #21 to select Page C. The display updates. The following message displays to
indicate current programming of that line or group of lines:
4. Press the RELEASE TIMER Button (Button #4) in the flexible button field. The following
message displays:
5. Enter a valid number on the dial pad which corresponds to 000-255 ms.
6. Press HOLD button to save entry. A confirmation tone sounds and the display updates.
DEFAULT ... Release Timer is set for 200 ms.
STARPLUS STSe - Programming & Operations Manual
CO L I N E AT T R I B U T E S
S E L EC T A CO L I NE R A NG E
If HOLD is pressed without entering a CO line range, all CO lines are selected.
XXX - XXX PAGE C
E N T E R B U T TO N N U MBE R
XXX-XXX = CO Line Range
R E LE A S E TI M ER
0 2 0
CO Line - Incoming Ringing Assignment
000-255
August 2005