ISDN Programming - Page A
2. Enter a valid number (0-9,*,#) on the dial pad (up to 24 digits). This number is sent as the
calling party number on all channels of the selected PRIB.
3. Press the HOLD button. A confirmation tone sounds and the display updates.

Max Out I-Frames

Description
The Max Out I-Frames feature controls the maximum number of sequentially numbered
I-Frames that may be outstanding/unacknowledged at any given time. This is a system
parameter which shall not exceed 127. Do not change the Max Out I-Frames setting unless
advised to do so by Technical Support.
Programming Steps
1. Press the MAX OUT I-FRAMES flexible button (FLASH 45, Page A, Button #7).
2. Enter a valid number (000-127) on the dial pad.
3. Press the HOLD button. A confirmation tone sounds and the display updates.

Leading 1

Description
0 disables the leading 1 from being sent to the CO when users dial national long distance
numbers. 1 enables the leading 1 to be sent to the CO on national long distance numbers. If
enabled, and the user does not dial a 1, the 1 will automatically be applied.
Programming Steps
1. Press the LEADING 1 flexible button (FLASH 45, Page A, Button #8).
2. Enter a 0 or 1 on the dial pad to enable/disable this feature.
[0] = Disabled
[1] = Enabled
3. Press the HOLD button. A confirmation tone sounds and the display updates.
DEFAULT ... Leading 1 is enabled.