2-10
Paging Time-Out Timer
Technical Manuals Online! - http://www.tech-man.com
2. Enter a valid number on the dial pad that corresponds to
01-99 minutes.
3. Press HOLD to save the entry. A confirmation tone is heard and the
display updates.
Description
The Conference/DISA Timer determines the time an unsupervised
conference can continue after the initiator of the conference has exited.
By default, the Conference/DISA Timer is set at 10 minutes and is variable
from 01–99 minutes. A 00 entry disables the timer and no automatic
disconnect occurs.
The Conference Timer also allows the system administrator to control
the time a DISA caller is allowed after establishing a Trunk-to-Trunk
call. At the expiration of the Conference Timer, a tone is presented to
both DISA parties, then one minute later the system automatically
releases both trunks.
The Conference Timer does not affect or control a DISA-to-Station call.
Programming Steps
1. Press the PAGING TIMEOUT TIMER flex button (FLASH 01,
Button #10). The following message displays:
PAG ING TIME OUT
15
2. Enter a valid number on the dial pad that corresponds to
01-60 seconds.
3. Press HOLD to save the entry. A confirmation tone is heard and the
display updates.
System Timers
0 0-6 0