Brocade Communications Systems StoreFabric SN6500B Reference page 913

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

ZEUS-1016
Message
Port is faulted due to port re-initialization failure on internal Port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port failed due to port re-initialization failure.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
ZEUS-1028
Message
Detected excessive Link resets on the port in a second. Slot <slot number>, Port
<port number>(<blade port number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the port received excessive link resets from peer port within 1 second and that exceeded
threshold.
Recommended
When this error is observed persistently, change the small form-factor pluggable (SFP) transceiver or
Action
cable on the peer port to which this port is connected.
Fabric OS Message Reference
53-1002749-01
5
ZEUS-1016
891