Brocade Communications Systems StoreFabric SN6500B Reference page 198

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
BL-1037
BL-1037
Message
Faulting chip in slot = <slot number>, miniS = <miniS number>,port = <port number>
due to BE/BI port fault.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that all ports on the chip have been disabled due to a fault on the chip.
Recommended
Make sure that the blade is seated correctly.
Action
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
Additional blade fault messages precede and follow this error, providing more information. Refer to other
error messages for recommended action.
If the message persists, replace the blade.
BL-1038
Message
Inconsistent FPGA image version detected, please reboot the switch for recovery.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the field-programmable gate array (FPGA) image version is incompatible with the software
version.
Recommended
Reboot the switch. If the message persists, replace the switch.
Action
BL-1039
Message
Inconsistent FPGA image version detected, faulting the blade in slot <slot
number>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the field-programmable gate array (FPGA) image version is incompatible with the software
version.
Recommended
Power cycle the blade using the slotPowerOff and slotPowerOn commands.
Action
If the message persists, replace the blade.