Brocade Communications Systems StoreFabric SN6500B Reference page 797

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

SNMP-1004
Message
Incorrect SNMP configuration.
Message Type
AUDIT | FFDC | LOG
Class
CFG
Severity
ERROR
Probable Cause
Indicates that the SNMP configuration is incorrect and therefore the SNMP service will not work correctly.
Recommended
Change the SNMP configuration to the default using the snmpConfig --default command.
Action
SNMP-1005
Message
SNMP configuration attribute, <Changed attribute>, has changed from <Old Value> to
<New Value>.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the SNMP configuration has changed. The modified parameter and the old and new
parameter values are displayed in the message.
Recommended
Execute the snmpConfig --show command to view the new SNMP configuration.
Action
SNMP-1006
Message
<SNMP Configuration group> configuration was reset to default.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the specified SNMP configuration group was reset to the factory default.
Recommended
Execute the snmpConfig --show command for the group to view the new SNMP configuration.
Action
Fabric OS Message Reference
53-1002749-01
5
SNMP-1004
775