CDR-1007
Message
S<slot number>,C<chip index>: Internal link errors have been reported, no hardware
faults identified, continuing to monitor for errors: flt1:0x<fault1_cnt>,
flt2:0x<fault2_cnt> thresh1:0x<threshold_used>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that some errors were found in hardware that may or may not impact the data traffic.
Recommended
No action is required.
Action
CDR-1008
Message
S<slot number>,C<chip index>: HW ASIC Chip warning Level 1 type = 0x<chip error
type>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may or may
not degrade the data traffic.
Recommended
Restart the system at the next maintenance window.
Action
CDR-1009
Message
S<slot number>,C<chip index>: HW ASIC Chip warning Level 2 type = 0x<chip error
type>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may or may
not degrade the data traffic.
Recommended
Restart the system at the next maintenance window.
Action
Fabric OS Message Reference
53-1002749-01
5
CDR-1007
209