5
AG-1021
AG-1021
Message
Unable to do Preferred-Failover of F_Port <port number>. Failover across different
fabric is not supported.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that failover across N_Ports connected to different fabrics is not supported.
Recommended
Change the preferred N_Port settings of the specified F_Port using the ag --prefset command.
Action
Choose the preferred N_Port so that it is in the same fabric as the primary N_Port of this F_Port. Execute
the ag --show command to check the fabric connectivity of the N_Ports.
AG-1022
Message
F_Port <f_port> is failed over to its preferred N_Port <n_port>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the specified F_Port is failing over to its preferred N_Port.
Recommended
Execute the ag --mapshow command to display the updated F_Port-to-N_Port mapping.
Action
AG-1023
Message
F_Port <f_port> mapped to offline N_Port <n_port> is failed over to its preferred
N_Port <preferred port>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified N_Port has failed to come online. The F_Port mapped to this N_Port had its
preferred set and is online.
Recommended
Execute the ag --mapshow command to display updated F_Port-to-N_Port mapping.