Brocade Communications Systems StoreFabric SN6500B Reference page 318

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
EM-2003
EM-2003
Message
<Slot Id or Switch for pizza boxes> has failed the POST tests. FRU is being
faulted.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test (POST). Refer to the
/tmp/post[1/2].slot#.log file for more information on the faults. To view this log file, you must be logged in
at the root level. The ID will be Switch for non-bladed systems.
Recommended
On bladed systems, reseat the specified FRU.
Action
On non-bladed switches, restart or power cycle the switch.
If the problem persists, perform the following actions:
296
Execute the
command to make sure that Power-On Self-Test (POST) is enabled; then
diagPost
power cycle the blade by using the
blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
On bladed systems, replace the specified FRU; otherwise, replace the switch.
and
slotPowerOff
slotPowerOn