5
SULB-1032
Recommended
Wait for the operation to complete.
Action
SULB-1032
Message
Relocating an internal firmware image on the CP.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
WARNING
Probable Cause
Indicates that the switch has started firmware download to the co-CPU.
Recommended
Wait for the operation to complete.
Action
SULB-1033
Message
Switch has completed relocating the internal firmware image.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
WARNING
Probable Cause
Indicates that the firmware download process has completed normally on the switch.
Recommended
Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
Action
make sure the switch is enabled.
SULB-1034
Message
Relocation of internal image timed out.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
ERROR
Probable Cause
Indicates that there may be an error caused by the switch initialization issue after the internal image is
relocated. It may also be caused by an internal Ethernet issue or by a persistent storage hardware
failure.
Recommended
Reboot the switch. This will cause the internal image to be relocated again. Use the
Action
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.