Brocade Communications Systems StoreFabric SN6500B Reference page 347

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

FABS-1014
Message
<Method name>[<Method tag number>]:Unknown FRU type 0x<FRU Object type>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an unrecognized type of field-replaceable unit (FRU) has been discovered in the system.
This may be caused by an incorrect FRU header, inability to read the FRU header, or the FRU may not
be supported by this platform or Fabric OS version.
Recommended
Verify that the FRU is valid for use in this system and this version of Fabric OS.
Action
Reseat the FRU.
If this is a valid FRU and reseating does not solve the problem, replace the FRU
FABS-1015
Message
<Method name>[<Method tag number>]:Request to enable FRU type 0x<FRU Object type>,
unit <Unit number> failed. err code <Error code>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the specified FRU could not be enabled. This is usually an internal Fabric OS problem.
Recommended
Remove and reinsert the FRU.
Action
Reboot or power cycle the CP or system.
If the message persists, run the firmwareDownload command to update the firmware.
Fabric OS Message Reference
53-1002749-01
5
FABS-1014
325

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents