Brocade Communications Systems StoreFabric SN6500B Reference page 164

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
ANV-1007
ANV-1007
Message
S<slot number>,C<chip index>: ANVIL PASS 1 low buff pool fault: <chip regval
field> 0x<chip error type>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that Anvil Pass 1 is running out of free buffers, which may cause chip fault.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
ANV-1008
Message
S<slot number>,C<chip index>: MAC-VID classifier table is full. No space for new
entry.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the Media Access Control (MAC) VLAN ID (VID) classifier table is full and no more entries
can be added.
Recommended
Delete some of the existing unused rules using the portcfg arp command and then add new entries.
Action
ANV-1015
Message
Port reinitialized due to Link Reset failure on internal port S<slot
number>,P<port number>(<blade port number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port is re-initialized due to link reset failure.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
142
Fabric OS Message Reference
53-1002749-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents