5
LOG-1000
LOG Messages
LOG-1000
Message
Previous message repeated <repeat count> time(s).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the previous message was repeated the specified number of times.
Recommended
No action is required.
Action
LOG-1001
Message
A log message was dropped.
Message Type
LOG | FFDC
Severity
WARNING
Probable Cause
Indicates that a log message was dropped. A trace dump file has been created.
Recommended
Execute the reboot command for non-bladed switches or the haFailover command on bladed switches.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
LOG-1002
Message
A log message was dropped.
Message Type
FFDC | LOG
Severity
WARNING
Probable Cause
Indicates that a message was not recorded by the error logging system. A trace dump file has been
created. The message may still be visible through Simple Network Management Protocol (SNMP) or
other management tools.
Recommended
Execute the reboot command for non-bladed switches or the haFailover command on bladed switches.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.