5
UCST-1003
UCST Messages
UCST-1003
Message
Duplicate Path to Domain <domain ID>, Output Port = <port number>, PDB pointer =
0x<value>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that duplicate paths were reported to the specified domain from the specified output port. The
PDB pointer value displayed in the message is the address of the path database and provides debugging
information.
Recommended
No action is required.
Action
UCST-1007
Message
Inconsistent route detected: Port = <port number>, should be <port number>.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the switch detected an inconsistency in the routing database between the routing protocol
and the hardware configuration. The first port number displayed is what the hardware has configured and
the second port number displayed is what the protocol is using.
Recommended
Run the switchDisable command and then the switchEnable command to reset the routing database.
Action
Run the uRouteShow command to display the new routing tables.
UCST-1020
Message
Static route (input-area: <port number>, domain: <domain ID> output-area: <port
number>) has been ignored due to platform limitation.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the configured static route cannot be applied to the routing database because of a platform
limitation.
Recommended
No action is required.
Action