Brocade Communications Systems StoreFabric SN6500B Reference page 828

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
SS-1003
SS-1003
Message
supportSave's operation to USB storage device aborted.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a USB operation error occurred during execution of the supportSave command. Complete
error information cannot always be displayed in this message because of possible errors in
subcommands being executed by the supportSave command.
Recommended
Execute the usbstorage command to check the USB storage device settings. After the USB problem is
Action
corrected, execute the supportSave command again.
SS-1004
Message
One or more modules timed out during supportsave. Retry supportsave with -t option
to collect all logs.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates a timeout in modules during the execution of the supportSave command.
Recommended
Execute the supportSave -t [2-5] command to collect all logs.
Action
SS-1005
Message
supportsave failed for the slot <Slot Number>. Reason: No IP connection.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there is no IP connection between the active control processor (CP) and the blade in the
specified slot.
Recommended
Check for the IP connection between the active CP and the blade in the specified slot. After the IP
Action
connection is established, execute the supportSave command again.
806
Fabric OS Message Reference
53-1002749-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents