SULB-1020
Message
New firmware failed to boot in slot <Slot number>.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
ERROR
Probable Cause
Indicates that the BP blade is still running the old image even though it should reboot with the new image.
This error may indicate that the new image has not been loaded correctly to the specified blade.
Recommended
Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn
Action
commands to trigger another firmware download to the blade. If the blade is stuck in LOADING state,
remove and re-insert the blade to trigger another firmware download. If the problem persists, contact
your switch service provider.
SULB-1021
Message
Firmware is being downloaded to the blade in slot <Slot number>.
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
WARNING
Probable Cause
Indicates that the firmware is being loaded to the specified blade.
Recommended
Run the firmwareDownloadStatus command to monitor the firmware download progress. After it
finishes, run the firmwareShow command to verify the firmware versions.
Action
SULB-1022
Message
The blade in slot <Slot number> has rebooted successfully with new firmware.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step in the
firmware download process.
Recommended
Run the firmwareDownloadStatus command to monitor the firmware download progress.
Action
Fabric OS Message Reference
53-1002749-01
5