BLS-1003
Message
An IPsec/IKE policy was deleted.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that an Internet Protocol Security (IPsec) or Internet Key Exchange (IKE) policy was deleted
and the configuration file was updated.
Recommended
No action is required.
Action
BLS-1004
Message
Tape Read Pipelining is being disabled slot (<slot number>) port (<user port
index>) tunnel (<The configured tunnel ID (0-7)>).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the Fabric OS version on the remote end of the tunnel does not support Tape Read
Pipelining.
Recommended
No action is required.
Action
BLS-1005
Message
S<slot number>,P<user port index>(<blade index>) [OID 0x<port OID>]: <string name
of ge>: port faulted due to SFP validation failure. Please check if the SFP is
valid for the configuration.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
Action
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.