5
ESW-1001
ESW Messages
ESW-1001
Message
Switch is not in ready state - Switch enable failed, switch status= 0x<switch
status>, c_flags = 0x<switch control flags>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the switch enable operation has failed.
Recommended
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
Action
transfers; then execute the supportSave command and contact your switch service provider.
ESW-1002
Message
Security violation: Unauthorized device <wwn name of device> tries to FLOGI to
port <port number>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified device is not present in the authorized profile list.
Recommended
Verify that the device is authorized to log in to the switch. If the device is authorized, execute the
Action
secPolicyDump command to verify whether the World Wide Name (WWN) of the specified device is
listed. If it is not listed, execute the secPolicyAdd command to add this device to an existing policy.
ESW-1003
Message
Slot ENABLED but Not Ready during recovery, disabling slot = <slot number>(<return
value>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.
Action
For a non-bladed switch, restart or power cycle the switch.