Brocade Communications Systems StoreFabric SN6500B Reference page 462

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
FW-1007
FW-1007
Message
<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the speed of the fan has risen above the high boundary. Fan problems typically contribute
to temperature problems.
Recommended
Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan
Action
field-replaceable unit (FRU).
FW-1008
Message
<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the speed of the fan has changed from a value outside of the acceptable range to a value
within the acceptable range. Fan problems typically contribute to temperature problems.
Recommended
No action is required. Consistently abnormal fan speeds generally indicate that the fan is failing. If this
Action
message occurs repeatedly, replace the fan field-replaceable unit (FRU).
FW-1009
Message
<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the state of the power supply has changed from faulty to functional or from functional to
faulty.
Recommended
If the power supply is functioning correctly, no action is required.
Action
If the power supply is functioning below the acceptable boundary, verify that it is seated correctly in the
chassis. Run the psShow command to view the status of the power supply. If the power supply continues
to be a problem, replace the faulty power supply.
440
Fabric OS Message Reference
53-1002749-01