5
SEC-1333
SEC-1333
Message
<Name of command> command failed. There are VF enabled switch(s) in fabric. <List
of databases rejecting distribution> db(s) distribution is blocked.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates there was an attempt to distribute PWD or IPFILTER databases from the fabric to a switch that
is VF-enabled
Recommended
Disable VF on all the switches that have VF-enabled if PWD or IPFILTER databases need to be
Action
distributed.
SEC-1334
Message
SSH Daemon is restarted.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the Secure Shell (SSH) daemon was not running and it was restarted.
Recommended
No action is required.
Action
SEC-1335
Message
Strict <Policy Name> policy is conflicting with domain <Domain Number>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the policy is conflicting with the domain.
Recommended
No action is required. The domain is denied by disallowing all its E_Ports connected to the fabric. If the
Action
domain should be allowed to merge with the fabric, then resolve the issue by making the conflicting
policies the same.