5
AG-1003
AG-1003
Message
Unable to failover N_Port <port number>. Failover across different fabric is not
supported.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the failover does not get blocked between two fabrics, although it is not a supported
configuration.
Recommended
Configure two or more N_Ports to connect to the same fabric; then execute the ag --failoverenable
Action
command to enable failover on these N_Ports.
AG-1004
Message
Invalid response to fabric login (FLOGI) request from the fabric for N_Port <port
number>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the
specified N_Port.
Recommended
Check the configuration of the fabric switch.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AG-1005
Message
FDISC response was dropped because F_Port <port number> is offline.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the F_Port connected to the host is offline, which caused the Fabric Discovery (FDISC)
response to drop.
Recommended
Check the configuration of the host connected to the specified F_Port.
Action