Brocade Communications Systems StoreFabric SN6500B Reference page 543

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

FW-1435
Message
Switch status change contributing factor Flash: usage out of range.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the flash memory usage is out of
range. The policy was set using the switchStatusPolicySet command.
Recommended
Execute the supportSave command to clear out the kernel flash.
Action
FW-1436
Message
Switch status change contributing factor Marginal ports: <Number of marginal
ports> marginal out of <Total number of ports> ports:config(<Percentage
configured> percent,<Actual threshold limit>). (Port(s) <port list>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of marginal ports is
greater than or equal to the policy set using the switchStatusPolicySet command. A port is faulty when
the port value is Link Loss, Synchronization Loss, Signal Loss, Invalid word, Protocol error, CRC error,
Port state change, or Buffer Limited Port is above the high boundary.
Recommended
Replace the faulty or deteriorating small form-factor pluggable (SFP). Execute the fwportdetailshow
Action
command to know the reason for marginal ports.
FW-1437
Message
Switch status change contributing factor Faulty ports: <Number of faulty ports>
faulty out of <Total number of ports> ports:config(<Percentage configured>
percent,<Actual threshold limit>). (Port(s) <port list>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of faulty ports is
greater than or equal to the policy set by the switchStatusPolicySet command. A port is considered
faulty due to hardware failure such as a faulty small form-factor pluggable (SFP) or port.
Recommended
Replace any faulty or deteriorating SFPs.
Action
Fabric OS Message Reference
53-1002749-01
5